Counter 0 Internal Output Signal

The Counter 0 Internal Output (Ctr0InternalOutput) signal is the output of Counter 0. This signal reflects the terminal count (TC) of Counter 0. The counter generates a terminal count when its count value rolls over. The two software-selectable output options are pulse on TC and toggle output polarity on TC. The output polarity is software-selectable for both options. The following figure shows the behavior of the Ctr0InternalOutput signal.

You can use Ctr0InternalOutput in the following applications:

Refer to Device Routing in MAX in the NI-DAQmx Help for more information.